IMPROVED ADVANCED LIFE SUPPORT SIMULATOR

Product code : ST/iSTANBUL
0,00
Tax Included
inTheStock
  • Special Plastic Special Plastic

KEY FEATURES

Anatomical Structure: Full Size Adult
Length: 173 cm
Width: 51 cm
Height: 22 cm
Weight: 26 kg

  • Not easily deformed special plastic
  • Realistic appearance and anatomical structure
  • Prominent nipples, xiphoid process and chest, rib structure
  • Easily movable head, neck, waist, arm and leg joints
  • Rechargeable feature
  • 6 hours of battery life
  • 10” Tablet as control panel
  • 55” virtual bedside monitor
  • Wireless control

GENERAL APPLICATIONS

  1. IV puncture, injection, transfusion, and drawing blood practices can be done from the basilic and cephalic veins of the bilateral forearm and dorsal surface of the hand.
  2. IM injection into bilateral deltoid and vastus lateralis muscles of the thigh region.
  3. IM hip injection in the ventrogluteal and dorsogluteal area.
  4. Intraosseous (intra-bone) intervention from the left leg. There will be a feeling of falling into the void like in the bone when the needle is inserted to the bone because of the realistic bone structure.
  5. Male-female urethral catheterization and bladder irrigation where realistic sphincter resistance can be felt.
  6. Ostomy (colostomy and ileostomy) care.
  7. Enema application using liquid.
  8. Pneumothorax application.
  9. Photosensitive pupils.
  10. Upon request, it can be installed together with the audio and video recording system.

AIRWAY

  1. There are oral cavity, tongue, teeth, glottis, epiglottis trachea, esophagus, right and left lung structures.
  2. Oral and nasal endotracheal intubation.
  3. LMA, LTA and combi tube applications.
  4. Feedback via the control panel on airway opening by giving the correct head and neck position.
  5. In case of applying artificial respiration without giving the head-neck position, the air is filled into the stomach can be monitored on the tablet.
  6. In endotracheal intubation application, the situation of sending the cannula to the trachea, right bronchus or esophagus and excessive pressure on teeth can be monitored through the control panel.
  7. After the intubation procedure, the intubation position can be evaluated with a stethoscope.

CPR AND CARDIOLOGY PRACTICES

  1. Unilateral brachial and radial; bilateral carotid and femoral pulses synchronized with the selected ECG rhythm and adjustable pulse intensity.
  2. Artificial respiration from mouth-to-mouth, mouth-to-nose and with balloon masks can be done at realistic scales. The ratio of the given air in terms of volume can be monitored via the control panel.
  3. Automatic self-breathing is available because of the built-in compressor in the simulator and the number of respirations per minute can be adjusted via the control panel.
  4. Realistic bilateral and unilateral chest rising.
  5. Valve system that prevents the return of the air given to the manikin.
  6. Steel spring system designed to perform heart massage at realistic values and to prevent collapse during the practices.
  7. Follow-up of CPR practices by keeping a time record through the control panel.
  8. 30 different ECG rhythms, which can be displayed through 4 ECG points and heart rate can be adjusted via the control panel.
  9. Real defibrillator with safe defibrillation (shock) points. Real defibrillator, AED and bedside monitor can be used. Real defibrillation, cardioversion, pace and AED applications can be done.
  10. Noninvasive blood pressure (BP) measurement: systolic (SBP) and diastolic (DBP) blood pressure values can be changed via the control panel. The Korotkoff sounds heard during the measurement are synchronized with the selected ECG rhythm rate. 

OTHER APPLICATIONS

  1. The diameter of pupils can be changed via the control panel.
  2. The simulator can be voiced with audio recordings such as crying, shouting, groaning, vomiting, coughing and normal breathing from the control panel or it can be voiced via the control panel for a realistic anamnesis practice.
  3. Ability to create instant and pre-created unlimited scenarios via the control panel.
  4. Pneumothorax operation that can be performed through the intercostal space. When intervention is made with the needle, the information that pneumothorax is performed can be obtained via the control panel. Air outlet can be observed from the place where the intervention is made.
  5. When needle cricothyrotomy is performed, the information about the transaction can be obtained from the control panel.
  6. Cyanosis is present on the lips and nails of the simulator. Occurrence of cyanosis can be adjusted by the user. The color level can be changed with the intervention made on the simulator.
  7. When an IV intervention is made from the arm with the injector, the administered drug is detected and the drug information can be obtained from the control panel.
  8. Lung, heart and bowel sounds can be listened on the simulator.
  9. There is a 55” virtual bedside monitor for use in the laboratory environment. The monitor shows EKG, SpO2, AWRR, EtCO2, Temp., NIBP values ​. These values ​​ can be adjusted via the control panel.
 
Removed from the Comparison List